Arambagh, Hooghly, West Bengal+91 70013 32549 · support@energicity.co.in

Energicity Engineering Services

Power Quality Audit, Harmonic Analysis & Electrical Thermography

Engineering-led electrical assessment for hospitals, nursing homes, diagnostic centres, cold storages, commercial facilities and industries serving Kolkata and West Bengal.

01 · Power Quality

Power Quality Audit in Kolkata & West Bengal

A power quality audit measures the electrical conditions that influence equipment performance, system reliability and operating cost. Energicity records the actual site behaviour before recommending corrective action.

What we measure and review

  • Voltage and current operating conditions
  • True power factor and reactive-power behaviour
  • Voltage/current imbalance and phase loading
  • Maximum demand and load pattern
  • APFC panel response and capacitor-step performance
  • Relevant electricity-bill parameters

Typical concerns

Low power factor, unstable PF, unexplained maximum demand, abnormal loading, neutral-current concerns, recurring electrical problems or sensitive electronic loads.

Power quality audit for a hospital electrical distribution panel

02 · Harmonics

Harmonic Analysis for UPS, VFD & Nonlinear Loads

Modern facilities use UPS systems, VFDs, SMPS power supplies, LED drivers, medical electronics and other nonlinear loads. These can distort current and voltage waveforms and may influence APFC behaviour, neutral current, heating and equipment reliability.

Study scope may include

  • Voltage THD and current THD
  • Harmonic spectrum and dominant orders
  • True PF versus displacement PF behaviour
  • Neutral-current and phase-loading observations
  • Relationship between nonlinear loads and system condition
  • Need for further mitigation study where justified
Power quality analyser performing harmonic analysis on an electrical panel

03 · Power Factor

Power Factor & APFC Panel Performance Study

Low or unstable power factor is not always solved by simply adding capacitors. We review load behaviour, reactive power, existing capacitor steps, APFC response and harmonic influence before recommending a correction strategy.

What we review

  • Existing and target power factor
  • Reactive power (kVAR) requirement
  • Capacitor-bank step sizes and switching behaviour
  • APFC relay response and operating condition
  • Maximum demand and transformer/loading context
  • Harmonic conditions relevant to capacitor application

Where useful, the study can include indicative financial impact or simple payback based on verifiable site data.

Power factor and APFC panel study in a cold storage electrical system

04 · Thermography

Electrical Thermography & Thermal Inspection

Infrared thermography checks electrical panels and connections under load to identify abnormal temperature rise that may point to loose connections, deteriorating contacts, overload or phase-temperature imbalance.

Typical inspection areas

  • LT panels and distribution boards
  • Busbars and cable terminations
  • MCB, MCCB, contactor and switching connections
  • APFC panels and capacitor-bank connections
  • Transformer-related accessible connections
  • Motor feeders and major load circuits

Thermography is most meaningful under representative operating load.

Electrical thermography survey of an energized electrical panel

05 · Electrical Safety

Electrical Safety & Load Assessment

Review distribution loading, phase balance, feeder conditions, panel health and visible operating concerns that may affect electrical reliability or safety.

  • Panel and distribution loading
  • Phase-current balance
  • Abnormal neutral-current patterns
  • Visible deterioration or overheating
  • Areas needing detailed earthing, protection or thermal investigation

What You Receive

Clear findings, not a generic checklist.

  • Important electrical observations
  • Measured operating data where applicable
  • Priority classification of concerns
  • Photographic evidence where relevant
  • Practical corrective and preventive recommendations

06 · Testing

Electrical Testing & Verification

Instrument-based testing of selected electrical systems to support maintenance, troubleshooting and condition assessment.

  • Earthing system measurements
  • Insulation-resistance testing
  • Operating voltage and current measurements
  • Load-condition verification
  • Selected continuity/system checks
  • Post-correction verification where included

Important

Energicity’s core testing work focuses on technical measurement, assessment and reporting. Where a specific statutory certificate requires a designated licensed or accredited authority, that requirement should be handled under the applicable regulation.

How We Work

Measurement Before Recommendation

01

Review

Understand the facility and concern.

02

Measure

Record relevant parameters.

03

Analyse

Interpret data and abnormal conditions.

04

Recommend

Prioritise practical actions.

05

Verify

Re-measure after correction if required.

Need an Engineering View?

Tell us what is happening at your facility.

You do not need to know the exact service name. Share your site concern, recent electricity bill or test information and we can suggest the appropriate assessment.

WhatsApp